KEPCO Industrial Partner

ABC 10-10DM - Kepco ABC 10-10DM Power Supply - Bench Power Supplies Simple...

larger image

Request Quote
For Price
Part Number:
ABC 10-10DM
Model Number:
ABC 10-10DM
Make:
KEPCO
Lead Time:
Available
Qty In Stock:
Available

Kepco ABC 10-10DM Power Supply - Bench Power Supplies Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • None Available

Specifications

    General
  • a-c Input Connections: Front:Panel ON/OFF switch; Rear:Detachable IEC 320 type connector; 3 wire fused
  • a-c Voltage: nominal:100-240V a-c, Single phase; range:85-264V a-c, Wide range
  • Adjustment range: 0 to 100%of rating Voltage/Current
  • Altitude: Sea level to 10,000 ft
  • Cooling: Natural convection
  • Current: 85V a-c:1.8A; 120V a-c:1.3A; 240V a-c:0.65A; 264V a-c:0.60A; all:Maximum at 100W output
  • Data Entry: Local:24 key keypad, Front panel; Remote:GPIB (IEEE 488.2), SCPI commands
  • Digital Display Front Panel: Voltage, current, mode, status, menu, program; 2 x 16 character alphanumeric LCD with LED backlight
  • Dimensions: 7.9" x 4.9" x 14" ±1/32"; 200.8 x 124.6 x 355.6 mm ±0.8 mm
  • EMC Emissions: Conducted:EN61000-3-2 Harmonics (0-2 KHz), EN61000-3-3 Fluctuation & Flicker, EN55022 Class B 0.15~30 MHz; Radiated:EN55022 Class B 30~1000 MHz
  • EMC Immunity To: Radiated RF:EN61000-4-3 Level 3; Magnetic Field:EN61000-4-8 Level 4; Electrostatic discharge:EN61000-4-2 Level 2 4KV contact, Level 3 8KV air discharge; Conducted RF:EN61000-4-6 Level 3; Electrical Fast Transient:EN61000-4-4 Level 3; Surges:EN61000-4-5 Level 4
  • Error Sense: 0.5V per wire, Voltage allowance
  • Frequency: nominal:50-60Hz, >63Hz Input leakage current exceeds spec; range:47-63Hz (400Hz), >63Hz Input leakage current exceeds spec
  • Humidity: operating & storage:0 to 95% RH Non condensing
  • Initial Turn-on Surge: 5A peak for less than 150 µsec; 85-264V a-c, 0-100% load
  • Isolation Voltage: 500V d-c or peak, Output to ground
  • Leakage Current: 120V a-c:<0.25mA, Source frequency in 47-63Hz range; 240V a-c:<0.5mA, Source frequency in 47-63Hz range
  • Load Effect: Voltage:<0.01% Eo max, 0 to 100% load change; Current:<0.02% Io max, 0 to 100% load change
  • Output Local Connections: Front:5 binding posts, ±Output; ±Sense; Ground; Rear:5 terminal barrier strips
  • Overshoot: None, Turn ON/OFF
  • Power Factor: min:120V:0.97, 100% load;240V:0.93, 100% load
  • Programming Accuracy: Voltage:0.025% Eo max; Current:0.1% Io max
  • Programming Time: 2ms max, 10%-90%
  • Rack Adapters: 5 1/4: x 19", RA 71:1 ABC unit; RA 72:2 ABC units
  • Readback/Display Accuracy: Voltage:0.05% Eo max; Current:0.1% Io max
  • Remote Control Programming: One standard GPIB connector; Rear SCPI & IEEE 488-2 commands
  • Shock: 20g, 11msec ±50% half sine, 3-axes 3 shocks each axis
  • Source Effect: Voltage:<0.01% Eo max, Nominal ± 15% of input voltage; Current:<0.01% Io max, Nominal ± 15% of input voltage
  • Temperature: Operating:0° to +50°C No derating 100% Po max, +50°C to +70°C Linear derating to 40% Po max; Storage:-40° to +85°C
  • Temperature Effect: Voltage:<0.01% Eo max, Per degree C (0 to 50°C); Current:<0.01% Io max, Per degree C (0 to 50°C)
  • Time Effect: Voltage:<0.01% Eo max 0.5-8.5 hours; Current:<0.01% Io max, 0.5-8.5 hours
  • Transient Recovery to Load Change: Excursion:<5% Eo max; 50%-100% load change return to 1% Eo max; Recovery:<200 µsec; 50%-100% load change return to 1% Eo max
  • Type of Stabilizer: Automatic crossover Voltage/Current
  • Vibration: 5-10Hz 10mm double amplitude, Non operating 1 hour each axis, 10-55Hz 2g
  • Weight: 15 lbs. / 6.8 Kg; Packed for shipping

 

Applications

  • None Available

Aliases